:TRIGger:TV:MODE

Command Syntax
:TRIGger:TV:MODE <mode>
<mode> ::= {FIEld1 | FIEld2 | AFIelds | ALINes | LINE | LFIeld1
The :TRIGger:TV:MODE command selects the TV trigger mode and field.
The LALTernate parameter is not available when :TRIGger:TV:STANdard is
GENeric.
Old forms for <mode> are accepted:
<mode>
FIEld1
FIEld2
AFIelds
ALINes
LFIeld1
LFIeld2
LALTernate
Query Syntax
:TRIGger:TV:MODE?
The :TRIGger:TV:MODE? query returns the TV trigger mode.
Return Format
<value><NL>
<value> ::= {FIE1 | FIE2 | AFI | ALIN | LINE | LFI1 | LFI2 | LALT}
See Also
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
(see
page
1138)
| LFIeld2 | LALTernate}
"Introduction to :TRIGger Commands"
":TRIGger:TV:STANdard"
":TRIGger:MODE"
on page 886
Old Forms Accepted
F1
F2
ALLFields, ALLFLDS
ALLLines
LINEF1, LINEFIELD1
LINEF2, LINEFIELD2
LINEAlt
on page 877