:ACTivity
Command Syntax
:ACTivity
The :ACTivity command clears the cumulative edge variables for the next
activity query.
Query Syntax
:ACTivity?
The :ACTivity? query returns whether there has been activity (edges) on
the digital channels since the last query, and returns the current logic
levels.
Because the :ACTivity? query returns edge activity since the last :ACTivity? query, you must
N O T E
send this query twice before the edge activity result is valid.
Return Format
<edges>,<levels><NL>
<edges> ::= presence of edges (16-bit integer in NR1 format).
<levels> ::= logical highs or lows (16-bit integer in NR1 format).
bit 0 ::= DIGital 0
bit 15 ::= DIGital 15
A bit = 0 (zero) in the <edges> result indicates that no edges were detected on that channel
N O T E
(across the specified threshold voltage) since the last query.
A bit = 1 (one) in the <edges> result indicates that edges have been detected on that
channel (across the specified threshold voltage) since the last query.
(The threshold voltage must be set appropriately for the logic levels of the signals being
probed.)
See Also
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
(see
page
1138)
"Introduction to Root (:) Commands"
":POD<n>:THReshold"
":DIGital<d>:THReshold"
on page 190
on page 527
on page 295