:TRIGger:USB:TRIGger

Command Syntax
:TRIGger:USB:TRIGger <value>
<value> ::= {SOP | EOP | ENTersuspend | EXITsuspend | RESet}
The :TRIGger:USB:TRIGger command sets where the USB trigger will occur:
• SOP — Start of packet.
• EOP — End of packet.
• ENTersuspend — Enter suspend state.
• EXITsuspend — Exit suspend state.
• RESet — Reset complete.
Query Syntax
:TRIGger:USB:TRIGger?
The :TRIGger:USB:TRIGger? query returns the current USB trigger value.
Return Format
<value><NL>
<value> ::= {SOP | EOP | ENTersuspend | EXITsuspend | RESet}