:TRIGger:RUNT:TIME

Command Syntax
:TRIGger:RUNT:TIME <time>[suffix]
<time> ::= floating-point number in NR3 format
[suffix] ::= {s | ms | us | ns | ps}
When triggering on runt pulses whose width is greater than or less than a
certain value (see :TRIGger:RUNT:QUALifier), the :TRIGger:RUNT:TIME
command specifies the time used with the qualifer.
Query Syntax
:TRIGger:RUNT:TIME?
The :TRIGger:RUNT:TIME? query returns the current runt pulse qualifier
time setting.
Return Format
<time><NL>
<time> ::= floating-point number in NR3 format
See Also
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
(see
page
1138)
"Introduction to :TRIGger Commands"
":TRIGger:RUNT:QUALifier"
on page 877
on page 929