:POWer:SIGNals:VSTeady:ONOFf:ON
Command Syntax
:POWer:SIGNals:VSTeady:ONOFf:ON <value>[suffix]
<value> ::= Expected steady state output Voltage value in NR3 format
[suffix] ::= {V | mV}
The :POWer:SIGNals:VSTeady:ONOFf:ON command specifies the expected
steady state output DC voltage of the power supply for turn on analysis.
Query Syntax
:POWer:SIGNals:VSTeady:ONOFf:ON?
The :POWer:SIGNals:VSTeady:ONOFf:ON query returns the expected steady
state voltage setting.
Return Format
<value><NL>
<value> ::= Expected steady state output Voltage value in NR3 format
See Also
•
•
•
•
•
•
•
•
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
(see
page
1138)
":POWer:ONOFf:APPLy"
":POWer:SIGNals:AUTosetup"
":POWer:SIGNals:DURation:ONOFf:ON"
":POWer:SIGNals:IEXPected"
":POWer:SIGNals:OVERshoot"
":POWer:SIGNals:VMAXimum:ONOFf:ON"
":POWer:SIGNals:SOURce:CURRent<i>"
":POWer:SIGNals:SOURce:VOLTage<i>"
on page 553
on page 564
on page 570
on page 573
on page 574
on page 577
on page 581
on page 582
24
:POWer Commands
579