At the MAP display
20
After you replace the faulty card, load the inactive RCC unit. To load the
inactive RCC unit, type
>LOADPM INACTIVE
and press the Enter key.
If load
passed
failed
21
To return the INACTIVE RCC unit to service, type
>RTS INACTIVE
and press the Enter key.
If the RTS
passed
failed
22
Send any faulty cards for repair according to local procedure.
23
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card.
Go to step 26.
24
Return to the Alarm Clearing Procedure that directed you to this card
replacement procedure. If necessary, go to the point where the faulty card list
was produced, identify the next faulty card on the list, and go to the
appropriate replacement procedure in this manual for that card.
25
Obtain further assistance in replacing this card by contacting personnel
responsible for higher level of support.
26
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RSC
Do
step 21
step 25
Do
step 22
step 25
1-489
NT2X70
(end)