Replacing an NT2X90 in an RMM
At your Current Location
1
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
At the MAP terminal
2
Access the trunk test position (TTP) level of the MAP display and post the
RMM that contains the card to be replaced by typing
>MAPCI;MTC;TRKS;TTP;POST P RMM rmm_no ckt_no to ckt_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
ckt_no
is the number of the trunk circuit associated with the card to be
replaced
Example of a MAP response :
POST
20
TTP 6–006
CKT TYPE
OG
MF RMM 0 0
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
3
Ensure the correct card is being pulled from the correct card slot by typing
>CKTLOC
and pressing the Enter key.
4
Busy the trunks associated with the card to be replaced by typing
>BSY ALL
and pressing the Enter key.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an IOPAC RMM
DELQ
BUSY Q
PM NO.
COM LANG
LTU
LTU
1-535
NT2X90
(continued)
DIG
STA S R DOT TE R
LO
P_IDL