Nortel DMS-100 Series Replacement Procedures page 208

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-176 XPM card replacement procedures
NT2X09
in an IOPAC RMM
22
23
24
25
26
27
28
29
297-8021-547 Standard 14.02 May 2001
(continued)
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files obtained in
step 19.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Go to step 28.
From office records, determine and note the number of the system load
module (SLM) disk and the number of the volume that contains the PM load
files.
Access the disk utility level of the MAP display by typing
>DISKUT
and pressing the Enter key.
List the SLM file names into your user directory by typing
>LV CM;LF file_name
and pressing the Enter key.
where
file_name
is the name of the SLM disk volume containing the PM load file
obtained in step 24.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Reload the RMM by typing
>LOADPM
and pressing the Enter key.
If
load failed
load passed
Return the RMM to service by typing
>RTS
Do
step 32
step 29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents