24
Power up the NT2X70 in slot 25 as follows:
If NT2X70 suffix is
AE
AA, AB, AC, or AD
25
Toggle the ON/OFF/RESET switch on the power converter faceplate,
identified in step 3 , to the RESET position and hold while setting CB1, on the
FSP, to the ON position. Both the converter FAIL LED and FRAME FAIL lamp
on the FSP will go OFF, release the ON/OFF/RESET switch.
26
Press the RESET button on the power converter faceplate while setting CB1,
identified in step 3 , on the FSP to the ON position. The converter FAIL LED
will go OFF, release the RESET button.
27
Set the power switch on the NT2X09 and NT2X06 power converters on the
RMM shelf to the ON position.
28
Press the RESET button on the NT2X09 power converter while setting CB5,
on the FSP to the ON position. Both the converter FAIL LED and FRAME
FAIL lamp on the FSP will go off.
29
Remove the wrist strap.
30
Determine if a Converter Fail LED is lit.
If Converter Fail LED is
lit
not lit
At the MAP display
31
Access the PM level of the MAP display by typing
>MAPCI;MTC;PM
and pressing the Enter key.
32
Post the LCM that is controlled by the alarm and control card you have just
replaced by typing
>POST LCM
and pressing the Enter key.
where
site_name
is the name of the site where the LCM is located
rame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM unit with the faulty card
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
site_name frame_no lcm_no
NT0X91AE
in an RLCE
Do
step 25
step 26
Do
step 47
step 31
1-111
(continued)