Nortel DMS-100 Series Replacement Procedures page 385

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the RMM shelf
3
Replace the NT2X57 card using the common replacing a card procedure in
this document. When you have completed the procedure, return to this point.
At the MAP display
4
Repost to verify the signal distribution circuits on the card that was replaced
by typing
>POST P RMM rmm_no ckt_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card was replaced
ckt_no
is the number of the first circuit where the NT2X57 card is physically
located.
Example of a MAP response:
LAST CIRCUIT = 14
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
13
TTP 6–006
CKT TYPE
OG TESTEQ RMM 0 0
5
Send any faulty cards for repair according to local procedure.
6
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 8.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RLCM RMM
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap grounding
point of a frame supervisory panel (FSP) while handling
circuit cards. This protects the cards against damage caused
by static electricity.
1147
DELQ
BUSY Q
PM NO.
COM LANG
OAUSD 0
1-353
NT2X57
(continued)
DIG
STA S R DOT TE R
IDL