Nortel DMS-100 Series Replacement Procedures page 513

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

CM
MS
.
.
RCC
0 Quit
2 Post_
3 ListSet
4
5 TRNSL_
6 TST_
7 BSY_
8 RTS_
9 OffL
10 LoadPM_
11 Disp_
12 Next_
13 SwAct
14 QueryPM
15
16 IRLINK
17 Perform
18
4
By observing the MAP display, be sure the card is to be removed is on the
inactive unit.
If the faulty card is on an
ACTIVE unit
INACTIVE unit
5
To switch the processing activity to the inactive unit, type
>SWACT
and press the Enter key.
The system determines the type of SwAct it can perform and displays a
confirmation prompt for the selected SwAct.
If SWACT
can continue at this time
cannot continue at this time
6
To switch the activity of the unit, type
>YES
and press the Enter key.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
IOD
Net
PM
.
.
1RCC
SysB
ManB
PM
0
0
RCC
0
0
RCC
0 ISTb
Unit 0:
Inact SysB
Unit 1:
Act
XPM card replacement procedures
in an RSC
CCS
LNS
Trks
.
.
.
OffL
CBsy
2
0
0
0
Links_OOS:
CSide
InSv
Do
step 5
step 8
Do
step 6
step 25
1-481
NT2X70
(continued)
Ext
APPL
.
.
ISTb
InSv
2
25
1
1
0,
PSide
0

Hide quick links:

Advertisement

Table of Contents
loading