Nortel DMS-100 Series Replacement Procedures page 197

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

in an RSC-S (PCM-30) Model A RMM
CM
MS
.
.
RMM
0 Quit
PM
2 Post_
RMM
3
4
RMM
5 Trnsl
6 Tst
7 Bsy
8 RTS
9 OffL
10 LoadPM
11 Disp_
12 Next
13
14 QueryPM
15
16
17
18
At the RMM shelf
5
Put on a wrist strap.
6
Power down the unit by setting the ON/OFF switch on the power converter
faceplate to the OFF position. Both the converter FAIL LED and FRAME FAIL
lamp on the frame supervisory panel (FSP) will be ON. An audible alarm may
sound. If an alarm does sound, return to the MAP terminal and silence the
alarm by typing
>sil
and pressing the Enter key.
7
Remove the NT2X06 card as shown in the following figures.
a
Locate the card to be removed on the appropriate shelf.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
IOD
Net
PM
.
.
1ManB
SysB
ManB
4
0
0
1
5
ManB
CAUTION
Static discharge may cause damage to circuit packs
Put on a wrist strap and connect it to the frame of the RMM
before removing any cards. This protects the RMM against
service degradation caused by static electricity.
CCS
LNS
Trks
.
.
.
OffL
CBsy
ISTb
10
0
0
0
1-165
NT2X06
(continued)
Ext
Appl
.
.
InSv
0
130
0
0