1-936 XPM card replacement procedures
NT6X27
in an OPM HIE
At the MAP display
15
16
17
18
19
297-8021-547 Standard 14.02 May 2001
(continued)
Test the links busied in step 12 by typing
>TST LINK link_no
and pressing the Enter key.
where
link_no
is one of two links associated with the replacement card
Note: Repeat this step for the other link associated with the replacement
card.
If test
failed
passed
Return to service the links busied in step 12 by typing
>RTS LINK link_no
and pressing the Enter key.
where
link_no
is one of two links associated with the replacement card
Note: Repeat this entry for the other link associated with the replacement
card.
If RTS
failed
passed
Determine if there are remaining links to clear.
If there are
remaining links to clear
no remaining links to clear
If you were directed to this procedure from another maintenance procedure,
return now to the procedure that directed you here and continue as directed.
Post the ILCM by typing
>POST ILCM site frame lcm_no
and pressing the Enter key.
where
Do
step 23
step 16
Do
step 23
step 17
Do
step 12
step 18

Hide quick links: