Nortel DMS-100 Series Replacement Procedures page 664

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-632 XPM card replacement procedures
NT3X09
in an RSC-S (DS-1) Model A RMM
11
At the MAP terminal
12
13
14
15
16
17
18
19
297-8021-547 Standard 14.02 May 2001
Use the following information to determine where to proceed.
If you entered this procedure
from
alarm clearing procedures
other
Test the RMM by typing
>TST
and pressing the Enter key.
If TST
passed
failed
Return the RMM to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
Post the MTADRIVER by typing
>TRKS;TTP;POST G MTADRIVER
and pressing the Enter key.
Return the MTADRIVER to service by typing
>BSY ALL;RTS ALL
and pressing the Enter key.
Send any faulty cards for repair according to local procedure.
Record the date the card was replaced, the serial number of the card, and the
symptoms that prompted replacement of the card. Go to step 20.
Return to the procedure that directed you to this procedure. At the point
where a faulty card list was produced, identify the next faulty card on the list
and go to the appropriate card replacement procedure for that card in this
manual.
Obtain further assistance in replacing this card by contacting operating
company maintenance personnel.
(continued)
Do
step 18
step 12
Do
step 13
step 18
Do
step 14
step 19