Nortel DMS-100 Series Replacement Procedures page 714

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-682 XPM card replacement procedures
NT4X97
in an RSC-S (PCM-30) Model B RMM
Replacing an NT4X97 card in RSC-S RMM
At the MAP
1
2
At the MAP terminal
3
4
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Obtain an NT4X97 replacement card. Ensure the replacement card has the
same product equipment code (PEC), including suffix, as the card that is to
be removed.
Set the MAP display to the PM level and post the RMM by typing
>MAPCI;MTC;PM;POST RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM where the card is to be removed
Example of MAP display:
CM
MS
IOD
.
.
.
RMM
SysB
0 Quit
PM
2 Post_
RMM
3
4
RMM
5
INSV
5 Trnsl
6 Tst
7 Bsy
8 RTS
9 OffL
10 LoadPM
11 Disp_
12 Next
13
14 QueryPM
15
16
17
18
Busy the RMM by typing
>BSY
(continued)
Net
PM
CCS
.
.
.
ManB
OffL
0
0
0
0
0
0
LNS
Trks
Ext
.
.
.
CBsy
ISTb
InSv
0
0
130
0
0
Appl
.
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents