And Pressing The Enter Key - Nortel DMS-100 Series Replacement Procedures

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-962 XPM card replacement procedures
NT6X30
in an RSC-S (DS-1) Model A LCME
Replacing an NT6X30 in RSC-S LCME
At your Current Location
1
2
At the MAP terminal
3
297-8021-547 Standard 14.02 May 2001
CAUTION
Loss of service
This procedure includes directions to manually busy one or
more peripheral module (PM) units. Since manually busying
a PM unit can cause service degradation, perform this
procedure only if necessary to restore out-of-service
components. Otherwise, carry out this procedure during
periods of low traffic.
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or were directed to this procedure by your maintenance
support group.
Obtain an approved replacement card.
Access the PM level and post the LCME by typing
>MAPCI;MTC;PM;POST LCME lcme _ site_name lcme_frame_no
lcme_no

and pressing the Enter key.

where
lcme_site_name
is the name of the site at which the LCME is located
lcme_frame_no
is the number of the frame in which the LCME is located
lcme_no
is the number of the LCME with the faulty card
Example of a MAP display
LCME RSCS 14 0 ISTb Links
Unit 0:
ISTb
Unit 1: InSv
Drwr:
01
23
..
..
(continued)
OOS: Cside 0 Pside 0
/RG:0
/RG:0
11
11
45
67
89
01
23
..
..
..
..
..
11
RG: Pref 0 ISTb
45
Stby 1 InSv
..

Hide quick links:

Advertisement

Table of Contents
loading