At the RCE/LCEI frame
14
Put on a wrist strap.
15
Turn the circuit breaker that powers the faulty ringing generator OFF. Ensure
that ringing generator 0 is on circuit breaker 03-65-01. Ensure that ringing
generator 1 is on circuit breaker 03-65-02.
16
Open the locking levers on the face of the card.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
in an RSC-S (DS-1) Model A LCME
WARNING
Static electricity damage
Before removing any cards, put on a wrist strap and connect
it to the wrist strap grounding point on the left side of the
frame supervisory panel (FSP) of the LCME. This protects
the equipment against damage caused by static electricity.
DANGER
Risk of personal injury
Ensure that you switch off the correct circuit breaker on the
FSP as described in the following steps. Do not proceed until
you have located and switched OFF the correct circuit
breaker for the RG you are replacing.
WARNING
Do not hold the card by the levers only
Holding a card by the locking levers only may break one or
both levers. Once the card has been pulled half way out of the
shelf, carefully grasp the card underneath for more secure
support and continue to remove the card from the shelf.
Avoid touching any wires or internal parts on the card.
XPM card replacement procedures
1-967
NT6X30