8
Installation busy the trunks that are associated with the new NT2X48 card by
typing
>BSY INB ALL
and pressing the Enter key.
Note: ESAdigitonereceiversshouldalwaysbeinanINBstatewhenthe
RLCM is under CC control, to prevent CC access. The ESA
processor will turn the circuits up to an idle state when the RLCM is in
the ESA environment.
9
Send any faulty cards for repair according to local procedure.
10
Record the following items in office records:
•
date the card was replaced
•
serial number of the card
•
symptoms that prompted replacement of the card
Go to step 12.
11
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
12
You have completed this procedure.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an OPM RMM
1-325
NT2X48