Nortel DMS-100 Series Replacement Procedures page 299

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT2X11 in an RMM
At your Current Location
1
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
At the MAP terminal
2
Access the trunk test position (TTP) level of the MAP display and post the
RMM that contains the card to be replaced by typing
>MAPCI;MTC;TRKS;TTP;POST P RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
Example of a MAP response:
POST
20
TTP 6–006
CKT TYPE
TE R
OG
MF RMM 0 0
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
3
Ensure the card being pulled is the correct card and is pulled from the correct
card slot by typing
>CKTLOC
and pressing the Enter key.
4
Busy the trunks associated with the card to be replaced by typing
>BSY ALL
and pressing the Enter key.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an OPAC RMM
DELQ
BUSY Q
PM NO.
COM LANG
LTU
OTDA00
1-267
NT2X11
(continued)
DIG
STA S R DOT
LO
P_IDL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents