Nortel DMS-100 Series Replacement Procedures page 491

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

9
If another maintenance procedure directed you to this procedure, return to
that procedure and continue as directed. If this action did not occur, proceed
to step 10.
At the MAP display
10
To load LCM unit 0, type
>LOADPM UNIT 0 CC
and press the Enter key.
If
you did not receive message
"loadfile not found in directory"
load passed
load failed
11
Determine the type of device that contains the PM load files.
If load files
are on tape
are on IOC disk
are on SLM disk
12
Locate the tape that contains the PM load files.
At the IOE frame
13
Mount the tape on a magnetic tape drive.
At the MAP display
14
To download the tape, type
>MOUNT tape_no
and press the Enter key.
where
tape_no
is the number of the tape drive that contains the PM load files
15
To list the contents of the tape in your user directory, type
>LIST T tape_no
and press the Enter key.
where
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RLCM-EDC HIE
Do
step 11
step 29
step 39
Do
step 12
step 18
step 23
1-459
NT2X70
(continued)

Hide quick links: