1-268 XPM card replacement procedures
NT2X11
in an OPAC RMM
At the RMM
5
At the MAP terminal
6
7
8
297-8021-547 Standard 14.02 May 2001
(continued)
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap grounding
point at the top of each equipment rack, (Bay 0, 1, 2, and 3),
while handling circuit cards. This protects the cards against
damage caused by static electricity.
Replace the NT2X11 card using the common replacing a card procedure in
this document. When you have completed the procedure, return here.
Post the RMM trunk circuits by typing
>POST P RMM rmm_no ckt_no to ckt_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
ckt_no
is the number of the trunk circuit associated with the card to be
replaced
Go to the PM level of the MAP screen, place the first circuit in a hold position
and test the second circuit by typing
>HOLD
and pressing the Enter key
and then typing
>TST
and pressing the Enter key.
If TST
passed
failed
Return to service the circuit tested by typing
>RTS
Do
step 8
step 14