Nortel DMS-100 Series Replacement Procedures page 572

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-540 XPM card replacement procedures
NT2X90
in an OPAC RMM
Replacing an NT2X90 in an RMM
At your Current Location
1
At the MAP terminal
2
3
4
297-8021-547 Standard 14.02 May 2001
(continued)
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
Access the trunk test position (TTP) level of the MAP display and post the
RMM that contains the card to be replaced by typing
>MAPCI;MTC;TRKS;TTP;POST P RMM rmm_no ckt_no to ckt_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
ckt_no
is the number of the trunk circuit associated with the card to be
replaced
Example of a MAP response :
POST
20
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
MF RMM 0 0
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
Ensure the correct card is being pulled from the correct card slot by typing
>CKTLOC
and pressing the Enter key.
Busy the trunks associated with the card to be replaced by typing
>BSY ALL
and pressing the Enter key.
BUSY Q
COM LANG
LTU
LTU
DIG
STA S R DOT TE R
LO
P_IDL