Replacing an NT6X21 card in an LCM
At your current location
1
Obtain a replacement card. Make sure the replacement card has the same
product equipment code (PEC), and PEC suffix, as the removed card.
At the MAP terminal
2
To access the LTP level of the MAP terminal and post the line, type
>MAPCI;MTC;LNS;LTP;POST L site lcm lsg ckt
and press the Enter key.
where
site
is the name of the site and the location of the RLCM-EDC
lcm
is the number of the RLCM-EDC LCM with the defective card
lsg
is the number of the line subgroup with the defective card
ckt
is the number of the circuit that associates with the defective card
Example of a MAP response:
LCC PTY RNG .....LEN.......... DN
PPHON
3
Check the status of the posted line.
If the line status is
manual busy (ManB)
not ManB
4
To busy the line, type
>BSY
and press the Enter key.
At the RLCC cabinet
5
Go to the common replacing a line card procedure in this document. When
the procedure is complete, return to this point.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RLCM-EDC LCM
REM1 00 0 03 03
STA F S LTA TE RESULT
7213355 MB
Do
step 5
step 4
1-881
NT6X21
(continued)