Nortel DMS-100 Series Replacement Procedures page 134

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-102 XPM card replacement procedures
NT0X91AE
in an OPM
(continued)
At the MAP display
31
32
33
34
35
36
37
38
297-8021-547 Standard 14.02 May 2001
Access the PM level of the MAP display by typing
>MAPCI;MTC;PM
and pressing the Enter key.
Post the LCM that is controlled by the alarm and control card you have just
replaced by typing
>POST LCM
site_name frame_no lcm_no
and pressing the Enter key.
where
site_name
is the name of the site where the LCM is locatedf
rame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM unit with the faulty card
Query the LCM for the name of the current PM load by typing
>QUERYPM
and pressing the Enter key.
Access the disk volume which contains the PM loads by typing
>DISKUT
and pressing the Enter key.
List the disk volume which contains the PM load files by typing
>LF
volume_name
and pressing the Enter key.
where
volume_name
is the name of the SLM disk volume containing the PM load files.
Quit the diskut environment by typing
>QUIT
and pressing the Enter key.
Load LCM unit 0 by typing
>LOADPM
UNIT 0 CC
and pressing the Enter key.
Return LCM unit 0 to service by typing
>RTS
UNIT 0
ALL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents