Nortel DMS-100 Series Replacement Procedures page 940

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-908 XPM card replacement procedures
NT6X21
in an RSC-S (PCM-30) Model A LCME
8
Recommended NT6X21AD S1 DIP switch settings (Sheet 1 of 2)
Recommended
application
P-phone sets long
loop: 19-24dB
EML
P-phone sets
medium loop:
17-19dB EML
Note: dB=decibel, NL = non-loaded, Vpp=voltage peak to peak, EML= estimatedmeasured loss, as
defined in NTP 297-2011-180 BCS35 version 01.02
297-8021-547 Standard 14.02 May 2001
a
Slide a card shroud over the card to be removed and an adjacent card. If
there is not an adjacent card on either side, do not use the card shroud.
b
Grasp the edge of the card with a line card extractor at a point midway
between the top and bottom edges. Hold the extractor in your right hand.
c
Squeeze the handles of the extractor together to grasp the card tightly.
d
Hold the front cover of the line drawer to steady it using your left hand.
e
Pull the extractor away from the drawer until the card becomes unplugged
from its socket on the drawer backplane.
f
Continue pulling the card with the extractor until the card is clear of the
shroud.
g
Insert the card removed into the ESD container and store using local
procedures.
Replace the faulty card using the following substeps:
a
Remove the replacement card from the ESD container.
If the line card suffix is
AA, AB, or AC
AD
b
Make DIP switch changes to the new replacement NT6X21AD line card
to match the DIP switch settings of the card being replaced, or as defined
in the following table.
D/A voice S1
Balance S2
switch position
switch position
ON
OFF
ON
-3.5d
0dB
B
NL
X
X
(continued)
Do
step c
step b
Signaling level S3 and S4
Both
OFF
ON
1.3Vp
9+2
p
X
X
X
Only
Only
Both
S4 ON
S3 ON
OFF
0.14Vp
0.8Vpp
0.6Vpp
p
X

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents