Nortel DMS-100 Series Replacement Procedures page 211

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Summary of card replacement procedure for an NT2X09 card in an RMM
At TTP level, post
the RMM
Is the RMM
status ManB?
N
Busy the trunks
associated with the
RMM
At PM level, post
and busy the RMM
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
Y
Power down the
RMM shelf
XPM card replacement procedures
in an OPM RMM
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
Replace card with
one having identical
PEC
1-179
NT2X09
(continued)
Power up the RMM
shelf
Reload the RMM
At PM level, return
RMM to service
At TTP level, post
the RMM and return
trunks to service
End of procedure

Hide quick links: