Nortel DMS-100 Series Replacement Procedures page 323

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT2X11 card in RSC-S RMM
At your Current Location
1
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
2
Obtain an NT2X11 replacement card. Ensure the replacement card has the
same product equipment code (PEC), including suffix, as the card that is to
be removed.
At the MAP terminal
3
Set the MAP display to TTP level and post the RMM by typing
>MAPCI;MTC;TRKS;TTP;POST G MTADRIVER
and pressing the Enter key.
Example of a MAP display:
CM
MS
.
.
TTP
0 Quit
2 Post_
3 Seize_
4
5 Bsy_
6 RTS_
7 Tst_
8
9 CktInfo
10 CktLoc
11 Hold
12 Next_
13 Rls_
14 Ckt_
15 Trnslvf_
16 Stksdr_
17 Pads_
18 Level_
4
Busy the MTADRIVER by typing
>BSY;BSY;INB;ALL
and pressing the Enter key.
Example of a MAP display:
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RSC-S (DS-1) Model A RMM
IOD
Net
PM
.
.
.
POST
1
TTP
6–009
CKT TYPE
PM NO.
MISC
RMM
0
16
TTP ID IS:
6–009
NO CKT, SET IS EMPTY
TTP:
LAST CKTN
=
1
SHORT CLLI IS:
MTADRI
OK, CKT POSTED
CCS
LNS
Trks
.
.
.
DELQ
BUSYQ
COM LANG
STA
S
R
MATDRIVER
0 IDL
1-291
NT2X11
(continued)
Ext
Appl
.
.
DIG
DOT TE RESULT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents