Nortel DMS-100 Series Replacement Procedures page 979

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X30 card in RSC LCM
At your Current Location
1
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure.
2
Obtain an approved replacement card.
At the MAP terminal
3
Access the PM level and post the LCM by typing
>MAPCI;MTC;PM;POST LCM site frame_no lcm_no
and pressing the Enter key.
where
site
is the name of the site at which the LCM is located
frame_no
is the number of the frame (00 to 511)
lcm_no
is the number of the LCM (0 or 1) in the frame
Example of a MAP response:
LCM REM1 00 0 ISTb Links
Unit 0: ISTb
Unit 1: InSv
Drwr:
01
23
..
..
4
Check the state of the PM units.
If the PM or PM units are
Offl or SysB
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
CAUTION
Loss of service
This procedure includes directions to manually busy one or
more peripheral module (PM) units. Since manually busying
a PM unit can cause service degradation, perform this
procedure only if necessary to restore out-of-service
components. Otherwise, carry out this procedure during
periods of low traffic.
OOS: Cside 0 Pside 0
/RG:0
/RG:0
11
11
45
67
89
01
23
..
..
..
..
..
in an RSC LCM
11
11
11
RG: Pref 0 ISTb
45
67
89
Stby 1 InSv
..
..
..
Do
step 5
1-947
NT6X30
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents