Nortel DMS-100 Series Replacement Procedures page 267

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT2X10 card in an RMM
At your current location
1
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
At the MAP display
2
Access the TTP level of the MAP and post the Line Test Unit to be replaced
by typing
>MAPCI;MTC;TRKS;TTP;POST T LTU ltu_no
and pressing the Enter key.
where
ltu_no
is the number of the faulty LTU
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
TTP 6–006
CKT TYPE
OG
3
Busy the trunks that are associated with the card to be replaced by typing
>BSY
and pressing the Enter key.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RLCM RMM
LTU
DELQ
BUSY Q
PM NO.
COM LANG
RMM 0 0
LTU
(continued)
DIG
STA S R DOT TE R
21
IDL
1-235
NT2X10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents