Advertisement

1-980 XPM card replacement procedures
NT6X30
in an RSC-S (DS-1) Model B LCME
13
297-8021-547 Standard 14.02 May 2001

frame_no

is the frame number (00 to 511) of the first LCME
lcme_no
is the number of the first LCM (0 or 1) in the frame,
site
is the LCM location (alphanumeric) of the second LCME
frame_no
is the frame number (00 to 511) of the second LCME
lcme_no
is the number of the second LCM (0 or 1) in the frame,
Example of command
>POST LCME RSC-S 14 0 RSC-S 14 1
Example of a MAP display:
LCME RSC-S 14 0 ISTb Links
Unit 0:
ISTb
Unit 1: InSv
Drwr:
01
23
45
..
..
..
Examine the other PM in the frame by typing
>NEXT
and pressing the Enter key.
Example of a MAP display:
LCME RSC-S 14 1 ISTb Links
Unit 0:
ISTb
Unit 1: InSv
Drwr:
01
23
45
..
..
..
If both PMs are
on the good RG
not on the good RG
Repeat step 3 through step 12 for the other PM provisioned in the equipment
frame.
(continued)
OOS: Cside 0 Pside 0
/RG:1
/RG:1
11
11
67
89
01
23
45
..
..
..
..
OOS: Cside 0 Pside 0
/RG:1
/RG:1
11
11
67
89
01
23
45
..
..
..
..
Do
step 14
step 13
11
RG: Pref 0 ISTb
Stby 1 InSv
..
11 RG: Pref 0 ISTb
Stby 1 InSv
..