Nortel DMS-100 Series Replacement Procedures page 308

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-276 XPM card replacement procedures
NT2X11
in an RLCM-EDC RMM
Replacing a NT2X11 card in RMM
At your current location
1
At the MAP display
2
3
At the RMM shelf
4
297-8021-547 Standard 14.02 May 2001
(continued)
Obtain a replacement card. Make sure that the replacement card has the
same product equipment code (PEC), including suffix, as the removed card.
To access the TTP level of the MAP display and post the line test unit (LTU)
associated with the damaged card, type
>MAPCI;MTC;TRKS;TTP;POST T LTU ltu_no
and press the Enter key.
where
ltu_no
is the number of the line test unit that has faults
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
RMM 0 0
To busy the trunks associated with the damaged card, type
>BSY
and press the Enter key.
Replace the NT2X11 card with the common replacing a card procedure in this
document. When you have completed the procedure, return to this point.
LTU
BUSY Q
COM LANG
LTU
21
DIG
STA S R DOT TE R
LO
P_IDL