Nortel DMS-100 Series Replacement Procedures page 388

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-356 XPM card replacement procedures
NT2X57
in an RSC RMM
Summary of card replacement procedure for NT2X57 card in an RSC RMM
At MAP PM level,
post the RMM
BSY the RMM
Replace the card
with one with
identical PEC
Directed to this
procedure from
other procedure?
N
Return the RMM to
service
297-8021-547 Standard 14.02 May 2001
(continued)
Return to alarm
Y
clearing or other
procedure
End of procedure
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.