Nortel DMS-100 Series Replacement Procedures page 45

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the RMM shelf
3
To replace the NT0X10 card use the common replacing a card procedure in
this document. When you complete the procedure, return to this point or go
to step 7.
4
To clear the trunk test position, type:
>NEXT
and press the Enter key.
Note: Repeat this command until the system clears the TTP control
position.
5
Send any defective cards for repair according to local procedure.
6
Record the following items in office records:
date you replaced the card
serial number of the card
problems that prompted replacement of the card.
Go to step 8.
7
For additional help, contact the next level of support.
8
This procedure is complete.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RLCM-EDC RMM
WARNING
Static electricity damage
Wear a wrist strap that connects to the wrist-strap grounding
point of a frame supervisory panel (FSP) to handle circuit
cards. The wrist strap protects the cards against static
electricity damage.
1-13
NT0X10
(end)