29
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
30
Reload the RMM by typing
>LOADPM
and pressing the Enter key.
If
load failed
load passed
31
Return the RMM to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
32
Go to the TTP level of the MAP and post the RMM by typing
>TRKS;TTP;POST P RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf in which the card is to be replaced
33
Return to service the circuits busied in step 7 by typing
>RTS ALL
and pressing the Enter key.
If
passed
failed
34
Send any faulty cards for repair according to local procedure.
35
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card