Nortel DMS-100 Series Replacement Procedures page 790

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-758 XPM card replacement procedures
NT6X18
in an RLCM
(end)
At the MAP terminal
6
7
8
9
10
11
297-8021-547 Standard 14.02 May 2001
There is a new diagnostics test for NT6X18AA/AB cards. This NT6X18 card
may be good. See the NT6X18 line card description in the general
maintenance section of this book for information on running an enhanced
diagnostics.
Test the line card just replaced by typing
>DIAG
and pressing the Enter key.
If DIAG
passed
failed
Return the line card to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 11.
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
You have successfully completed this procedure.
ATTENTION
Do
step 7
step 10
Do
step 8
step 10