Nortel DMS-100 Series Replacement Procedures page 636

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-604 XPM card replacement procedures
NT3X09
in an OPM RMM
5
At the shelf
6
At the MAP terminal
7
8
297-8021-547 Standard 14.02 May 2001
(continued)
Busy the trunks that are associated with the card to be replaced by typing
>BSY ; NEXT
and pressing the Enter key.
Note: Repeat this step for all circuits associated with the faulty
NT3X09AA/BA card to be replaced.
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap grounding
point of a frame supervisory panel (FSP) while handling
circuit cards. This protects the cards against damage caused
by static electricity.
Replace the NT3X09 card using the common replacing a card procedure in
this document. When you have completed the procedure, return to this point.
Post the new NT3X09 card by typing
>POST P RMM rmm_no ckt_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf in which the card is to be replaced
ckt_no
is the number of the first circuit where the NT3X09 card is physically
located
Return to service the circuits busied in step 5 by typing
>RTS ;NEXT
and pressing the Enter key.
Note: Repeat this step for all circuits associated with the new NT3X09
card.
If RTS
passed
failed
Do
step 15
step 17