Replacing an NT6X20 card in an RSC LCM
At your current location
1
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or were directed to this procedure by your maintenance
support group.
2
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC) including suffix, as the card that is to be
removed.
At the MAP terminal
3
Post the LEN of the card to be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site lcm_no lsg_no ckt_no
and pressing the Enter key.
where
site
is the site name given to the remote location
lcm_no
is the number of the LCM with the faulty card
lsg_no
is the number of the LSG with the faulty card
ckt_no
is the number of the circuit associated with the faulty card
Example of a MAP display:
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RSC LCM
1-841
NT6X20
(continued)