Nortel DMS-100 Series Replacement Procedures page 440

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-408 XPM card replacement procedures
NT2X59
in an RSC RMM
Replacing an NT2X59 card in RSC RMM
At your current location
1
2
At the MAP display
3
4
297-8021-547 Standard 14.02 May 2001
(continued)
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC) including suffix, as the card to be removed.
Access the PM level and post the RMM by typing
>MAPCI;MTC;PM;POST RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM from which the card is to be removed
Example of a MAP display:
CM
MS
IOD
.
.
.
RMM
SysB
0 Quit
PM
2 Post_
RMM
3
4
RMM
5
INSV
5 Trnsl
6 Tst
7 Bsy
8 RTS
9 OffL
10 LoadPM
11 Disp_
12 Next
13
14 QueryPM
15
16
17
18
Busy the RMM by typing
>BSY
and pressing the Enter key.
Net
PM
CCS
.
4SysB
.
ManB
OffL
4
0
10
0
1
1
LNS
Trks
Ext
.
.
.
CBsy
ISTb
3
3
0
0
APPL
.
InSv
130
2