Nortel DMS-100 Series Replacement Procedures page 571

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Summary of card replacement procedure for an NT2X90 in an RMM
At TTP level, post
the RMM
Busy the trunks
associated with the
card
At PM level, post
and busy the RMM
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
Y
Is the RMM
status ManB?
N
XPM card replacement procedures
in an OPAC RMM
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
Replace card with
one having identical
PEC
At PM level, post
the RMM and return
it to service
At TTP level, post
the RMM and return
trunks to service
End of
procedure
1-539
NT2X90
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents