Nortel DMS-100 Series Replacement Procedures page 88

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-56 XPM card replacement procedures
NT0X91
in an IOPAC FSP
42
43
44
45
At the MAP display
46
47
48
297-8021-547 Standard 14.02 May 2001
(continued)
Set the power switch on the NT2X09 and NT2X06 power converters on the
RMM shelf to the ON position.
Press the RESET button on the NT2X09 power converter while you set CB5
on the FSP to the ON position. Both the converter FAIL LED and FRAME
FAIL lamp on the FSP go off.
Remove the wrist strap.
Determine if a Converter Fail LED is lit.
If Converter Fail LED
is lit
is not lit
To post the LCM that the alarm and control card you replaced control, type
>POST LCM
site_name frame_no lcm_no
and press the Enter key.
where
site_name
is the name of the site where the LCM is located
frame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM unit with the new FSP card
To load the LCM unit, type
>LOADPM UNIT 0 CC
and press the Enter key.
If
message loadfile
found in directory is not
received
load passed
load failed
To query the LCM for the name of the current PM load, type
>QUERYPM
and press the Enter key.
Example of a MAP response:
Do
step 75
step 46
Do
step 48
not
step 69
step 75