Nortel DMS-100 Series Replacement Procedures page 965

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X27 card in an HIE
At your current location:
1
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
2
If you were directed to this procedure from another maintenance procedure,
go to step 4; otherwise, continue with step 3.
At the MAP display
3
Access the PM level and post the ILCM by typing
>MAPCI;MTC;PM;POST ILCM site frame lcm_no
and pressing the Enter key.
where
site
is the name of the PRLCM site (alphanumeric)
frame
is the frame number of the PRLCM cabinet
lcm_no
is the number of the PRLCM ILCM
4
Display C-side link information by typing
> TRNSL C
and pressing the Enter key.
Example of a MAP response:
Link 0: PLGC 0
Link 1: PLGC 0
5
From the display in step 4, determine the C-side peripheral module (PLGC,
or RCO2) to which the PRLCM is connected and post it by typing
> POST host_pm host_pm_no
and pressing the Enter key.
where
host_pm
is the name of the host PM ( PLGC, or RCO2)
host_pm_no
is the number of the host PM
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an OPM HIE
PLGC P-side link numbers
2; Cap MS; Status: OK
6; Cap MS; Status: SysB
1-933
NT6X27
(continued)
;MsgCond: OPN
;MsgCond: CLS