Test the inactive SMA unit by typing
>TST UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the SMA unit loaded in step 21
If TST
passes
fails
23
Return the inactive SMA unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the SMA unit tested in step 22
If RTS
passes
fails
At the equipment frame
24
Remove the sign from the active SMA unit.
25
Send any faulty cards for repair according to local procedure.
26
Note the following in the office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 28.
27
For further assistance, contact the personnel responsible for the next level of
support.
28
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.