Nortel DMS-100 Series Replacement Procedures page 981

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7
The next action depends on the type of LCM alarm indicated.
If the alarm is
critical
major or minor
8
Switch RG activity for the PM unit assigned to the faulty RG by typing
>SWRG UNIT unit_no
and pressing the Enter key.
where
unit_no
is the PM unit number (0 or 1)
Example of a MAP response:
LCM REM1 00 0 Unit 0 SWRG Passed
Note: Repeat this command for the other PM units assigned to the faulty
RG.
If the SWRG
passed
failed
9
Manually-busy (ManB) the PM unit associated with the faulty RG by typing
>BSY UNIT unit_no
and pressing the Enter key.
where
unit_no
is the PM unit number (0 or 1) associated with the faulty RG
Note: If clearing a critical alarm choose either unit to work on.
Example of a MAP response:
LCM REM1 00 0 Unit 0 Bsy Passed
Note: Repeat this command for the other PM in the frame.
If the BSY command
passed
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RSC LCM
Do
step 9
step 8
Do
step 9
step 38
Do
step 11
1-949
NT6X30
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents