1-126 XPM card replacement procedures
NT2X06
in an OPM RMM
19
20
21
22
23
24
25
26
27
28
297-8021-547 Standard 14.02 May 2001
(continued)
tape_no
is the number of the tape drive containing the PM load files
Demount the tape drive by typing
>DEMOUNT T tape_no
and pressing the Enter key.
wherewhere
tape_no
is the number of the tape drive containing the PM load files
Go to step 30.
From office records, determine and note the number of the input/output
controller (IOC) disk and the name of the volume that contains the PM load
files.
Access the disk utility level of the MAP by typing
>DSKUT
and pressing the Enter key.
List the IOC file names into your user directory by typing
>LISTVOL volume_name ALL
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files obtained in
step 21.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Go to step 30.
From office records, determine and note the number of the system load
module (SLM) disk and the name of the volume that contains the PM load
files.
Access the disk utility level of the MAP by typing
>DISKUT
and pressing the Enter key.
List the SLM file names into your user directory by typing
>LV CM;LF
Volume_name
and pressing the Enter key.
where
Volume_name
is the name of the volume containing the PM load files, obtained in
step 26.