Nt2X90 In An Iopac Rmm - Nortel DMS-100 Series Replacement Procedures

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-534 XPM card replacement procedures
NT2X90
in an IOPAC RMM
Summary of card replacement procedure for an NT2X90 in an RMM
At TTP level, post
the RMM
Busy the trunks
associated with the
card
At PM level, post
and busy the RMM
297-8021-547 Standard 14.02 May 2001
(continued)
Y
Is the RMM
status ManB?
N
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
Replace card with
one having identical
PEC
At PM level, post
the RMM and return
it to service
At TTP level, post
the RMM and return
trunks to service
End of
procedure