Nortel DMS-100 Series Replacement Procedures page 781

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X18 in an LCM
At the MAP
1
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
At the MAP terminal
2
Access the line test position (LTP) level of the MAP display and post the line
associated with the card to be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site rlcm lsg ckt
and pressing the Enter key.
where
site
is the name of the site where the OPAC is located
rlcm
is the number of the OPAC with the faulty card
lsg
is the number of the line subgroup with the faulty card
ckt
is the number of the circuit associated with the faulty card
Example of a MAP response:
LCC PTY RNG .....LEN..........
1FR
REM1 00 0 03 03
3
Check the status of the posted line.
If the line status is
manual busy (ManB)
not Man B
4
Busy the line by typing
>BSY
and pressing the Enter key.
At the LCM
5
Go to the common replacing a line card procedure in this document. When
you have completed the procedure, return here.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an OPAC LCM
DN
STA F S LTA TE RESULT
7213355 MB
Do
step 5
step 4
1-749
NT6X18
(continued)