Nortel DMS-100 Series Replacement Procedures page 798

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-766 XPM card replacement procedures
NT6X18
in an RSC LCM
11
12
13
14
15
16
297-8021-547 Standard 14.02 May 2001
(end)
Diagnostics. This option allows the line to be tested against a smaller
subset of ground start diagnostics. Therefore, when option NPGD is set in
table LENLINES, loop detector, reversal relay, and ground start relay tests
are skipped.
Return the NT6X18 card to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of card
Go to step 16.
Return to the Alarm Clearing Procedure that directed you to this procedure.
At the point where the faulty card list was produced, identify the next faulty
card on the list and go to the appropriate card replacement procedure for that
card in this manual.
Obtain further assistance in replacing this card by contacting personnel
responsible for a higher level of support.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.