Nortel DMS-100 Series Replacement Procedures page 972

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-940 XPM card replacement procedures
NT6X27
in an RLCM HIE
Replacing an NT6X27 card in an HIE
At your current location:
1
2
At the MAP display
3
4
Link 0: PLGC 0
Link 1: PLGC 0
5
297-8021-547 Standard 14.02 May 2001
(continued)
Obtain a replacement card. Make sure the replacement card has the same
product equipment code (PEC) and PEC suffix, as the card to be removed.
If another maintenance procedure directs you to this procedure, go to step 4.
If another procedure does not direct you to this procedure, go to step 3.
To access the peripheral module (PM) level and post the international line
concentrating module (ILCM), type:
>MAPCI;MTC;PM;POST ILCM site frame lcm_no
and press the Enter key.
where
site
is the name of the PRLCM site (alphanumeric)
frame
is the frame number of the PRLCM cabinet
lcm_no
is the number of the PRLCM ILCM
To display C-side link information, type:
> TRNSL C
and press the Enter key.
Example of a MAP response:
Use the display in step 4 to determine the central side (C-side) PM (PLGC, or
RCO2) that connects to the PRLCM. To post this module, type:
> POST host_pm host_pm_no
and press the Enter key.
where
host_pm
is the name of the host PM (PLGC, or RCO2)
host_pm_no
is the number of the host PM
PLGC P-side link numbers
2; Cap MS; Status: OK
6; Cap MS; Status: SysB
;MsgCond: OPN
;MsgCond: CLS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents