Nortel DMS-100 Series Replacement Procedures page 309

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP display
5
To test the new NT2X11 card, type
>TST
and press the Enter key.
If TST
passed
failed
6
To return to service the circuits busied in step 3, type
>RTS
and press the Enter key.
If RTS
passed
failed
7
To send the faulty cards for repair follow the local procedures.
8
Record the items that follow in office records:
date the replaced card
serial number of the card
indications that prompted replacement of the card
Go to Step 10
9
To replace this card you can obtain additional help. For additional help
contact the personnel responsible for next level of support.
10
You have completed this procedure.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RLCM-EDC RMM
Do
step 6
step 9
Do
step 7
step 9
1-277
NT2X11
(end)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents