Nortel DMS-100 Series Replacement Procedures page 982

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-950 XPM card replacement procedures
NT6X30
in an RSC LCM
10
11
12
13
297-8021-547 Standard 14.02 May 2001
(continued)
If the BSY command
failed
The next action depends on the type of PM alarm indicated.
If the alarm is
critical
major or minor
The next action depends on how many LCMs are provisioned in the
equipment frame.
If there
is one LCM provisioned in the frame
two LCMs provisioned in the frame, and you have
not switched RG activity for both LCMs
two LCMs provisioned in the frame, and you have
switched RG activity for both LCMs
Repeat steps 3 to 11 for the other LCM provisioned in the equipment frame.
Post both PMs in the frame and ensure all units are now on the good RG by
typing
>POST LCM site frame_no lcm_no site frame_no lcm_no
and pressing the Enter key.
where
site
is the PM location (alphanumeric) of the first LCM
frame_no
is the frame number (00 to 511) of the first LCM
lcm_no
is the number of the first LCM (0 or 1) in the frame,
site
is the LCM location (alphanumeric) of the second LCM
frame_no
is the frame number (00 to 511) of the second LCM
lcm_no
is the number of the second LCM (0 or 1) in the frame,
Example of command
>POST LCM REM1 00 0 REM1 00 1
Example of a MAP display:
Do
step 38
Do
step 15
step 11
Do
step 15
step 12
step 13